Where are the oil platforms in Google Earth? INFO: No binding policy redirect found. Could you please provide me with the correct redistributable packages? If so, can he download the VC++ redistribution package and install it, and will all be well then? navigate here

INFO: Post policy assembly identity is Microsoft.VC80.CRT,processorArchitecture="x86",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",version="8.0.50727.6195". All side by side binaries go in the winsxs folder located in C:\Windows. Now I'm at the point, where it's getting weired for me. Tracing log is saved to FileName. http://stackoverflow.com/questions/9110184/winsxs-fails-to-load-vc-dlls

Reply Nibu Thomas says: January 3, 2016 at 8:58 am Not sure what's going on. INFO: Begin assembly probing. How to determine enemy ammo levels Is it permitted to not take Ph.D. What should I do?

Side by Side errors are hard to figure out hence there is a dedicated tool to help figure the errors out. ERROR: Activation Context generation failed. INFO: Begin assembly probing. INFO: Did not find the assembly in WinSxS.

If 762 is by version higher than 6195, it should be as I've written: the WinSxS policy file should redirect 6195 to 762 - but it doesn't. –Matthias Feb 2 '12 INFO: End assembly probing. You are a true genius and a gentleman. navigate here INFO: Resolving reference for ProcessorArchitecture x86. > INFO: Resolving reference for culture Neutral. > INFO: Applying Binding Policy. > INFO: Find publisher policy at C:\Windows\WinSxS\manifests\x86_policy.8.0.microsoft.vc80.crt_1fc8b3b9a1e18e3b_8.0.50727.4940_none_516d712b0f495a45.manifest > INFO: No binding policy redirect

INFO: Did not find the assembly in WinSxS. INFO: No publisher policy found. One VC++ DLL is a C++/CLI DLL, which I use as public interface from my .NET project. Please use sxstrace.exe for detailed diagnosis.

INFO: Applying Binding Policy. http://georgelache.blogspot.com/2013/02/problem-machine-is-missing-correct-c.html Stoptrace Stop the trace if it is not stopped before. INFO: Resolving reference for ProcessorArchitecture x86. Please note the dll’s are debug binaries else you could have just installed the redist’s.

Your help would be much appreciated. INFO: Resolving reference Microsoft.Windows.Common-Controls.mui,language="*",processorArchitecture="x86",publicKeyToken="6595b64144ccf1df",type="win32",version="6.0.7601.17514". AppOutputFileName.exe.embed.manifest How is a manifest embedded into an application? INFO: No publisher policy found.

Not the answer you're looking for? INFO: Auto Servicing Policy redirected assembly version. INFO: No publisher policy found. http://oncarecrm.com/error-cannot/error-cannot-resolve-hostname-samsung.html INFO: Begin assembly probing.

Both applications are from Cyberlink. INFO: Attempt to probe manifest at C:\Program Files (x86)\ThinkPad\Utilities\en-US\Microsoft.Windows.Common-Controls.DLL. INFO: Begin assembly probing.

I didn't find a VC++ 2005 Redist Package with version 8.0.50727.6195 at Microsoft Download, the current VC++ 2005 Redist package comes in version 8.0.50727.762.

sxstrace shows the following (shortened): INFO: Reference: Microsoft.VC80.CRT,processorArchitecture="x86",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",version="8.0.50727.6195" INFO: Reference: Microsoft.VC80.OpenMP,processorArchitecture="x86",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",version="8.0.50727.6195" INFO: Resolving reference Microsoft.VC80.CRT,processorArchitecture="x86",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",version="8.0.50727.6195" ... INFO: Did not find the assembly in WinSxS. I suspect there's a cap on the size of posts. Trace will be saved to file SxsTrace.etl.

I know that there's a policy file for Microsoft.VC80.CRT in winsxs that redirects all versions of this assembly to the current version 8.0.50727.762 (that's the solution for the problem at http://blogs.msdn.com/b/nikolad/archive/2007/03/29/a-solution-to-two-references-to-different-versions-of-crt-mfc-atl-in-one-application-manifest-file.aspx). INFO: Attempt to probe manifest at C:\Program Files\CyberLink\PhotoDirector5\Kernel\CES\PDR.X\PDR.X.MANIFEST. INFO: Resolving reference for culture en. INFO: Resolving reference for culture en-US.